Lifecycle

The life cycle refers to all the states that a bare metal server goes through from creation to deletion. This chapter briefly describes the details of each state and the transitions between states.

Figure 1 BMS states

Table 1 Description of BMS states

State Attribute Description API Status
Creating Intermediate state A BMS is in this state after you request for the BMS and before it enters the running state.
If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.
BUILD/BUILDING
Starting Intermediate state It is an intermediate state between Stooed and Runnig.
If a BMS remians in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions.
SHUTOFF
Running Stable state A BMS is in this state when it is running properly.
A BMS in this state can be used normally.
ACTIVE
Stopping Intermediate state It is an intermediate state between Runnig and Stopped.
If a BMS remians in this state for a long time,exceptions will occur. Contact the administrator to handle the exceptions.
ACTIVE
Stopped Stable state A BMS is in this state after it is stopped successfully.
A BMS in this state cannot be used.
SHUTOFF
Restarting Intermediate state A BMS is in this state when it is being restarted.
If a BMS remains in this state for a long time, exceptions will occur.
Contact the administrator to handle the exceptions.
REBOOT
Forcibly restarting Intermediate state A BMS is in this state when it is being forcibly restarted. HARD_REBOOT
Deleting Intermediate state A BMS is in this state when it is being deleted. If a BMS remains in this state for a long time, exceptions will occur. Contact the administrator to handle the exceptions. ACTIVE/SHUTOFF/
REBOOT/HARD_REBOOT
/ERROR
Deleted Intermediate state A BMS is in this state after it is deleted successfully. A BMS in this state cannot be used and will be removed from the system in a short time. DELETED
Faulty Stable state A BMS is in this state when an exception occurs on it.A BMS in this state cannot be used. Contact the administrator to rectify the fault. ERROR
Rebuilding Intermediate state A BMS is in this state when it is being rebuilt. SHUTOFF
Reinstalling OS Intermediate state A BMS is in this state when its OS is being reinstalled. SHUTOFF
Reinstalling OS failed Stable state An exception occurred when the BMS OS was being reinstalled and the reinstallation failed.A BMS in this state cannot be used. Contact the administrator to rectify the fault. SHUTOFF
Freeze Stable state Bare metal server orders are stopped by the system administrator due to expiration or arrears. The server in this state cannot provide services to the outside world and needs to contact the administrator for processing. SHUTOFF
Lock Intermediate state / Stable state The BMS display is locked and in a protected state. At this time, some operations will be disabled. Please refer to the interface prompts for details.