作者:东方蜘蛛 发表于:2007-07-03 18:25:37
[size=2]硬件环境:2xE3500+2xA5200
软件环境:Solaris 2.6+Sun Cluster2.2+vxvm3.0[/size]
[size=2]一、故障硬盘更换前系统情况:[/size]
# uname -aSunOS fsmsdb1 5.6 Generic_105181-29 sun4u sparc SUNW,Ultra-Enterprise
# hastatGetting Information from all the nodes ...... HIGH AVAILABILITY CONFIGURATION AND STATUS -------------------------------------------LIST OF NODES CONFIGURED IN CLUSTER fsmsdb1 fsmsdb2CURRENT MEMBERS OF THE CLUSTER fsmsdb1 is a cluster member fsmsdb2 is a cluster memberCONFIGURATION STATE OF THE CLUSTER Configuration State on fsmsdb1: Stable Configuration State on fsmsdb2: StableUPTIME OF NODES IN THE CLUSTER uptime of fsmsdb1: 3:29pm up 456 day(s), 13:03, 1 user, load average: 0.62, 0.67, 0.71 uptime of fsmsdb2: 3:28pm up 429 day(s), 22:22, 0 users, load average: 0.01, 0.02, 0.03LOGICAL HOSTS MASTERED BY THE CLUSTER MEMBERSLogical Hosts Mastered on fsmsdb1: fsmsdbLogical Hosts for which fsmsdb1 is Backup Node: NoneLogical Hosts Mastered on fsmsdb2: NoneLogical Hosts for which fsmsdb2 is Backup Node: fsmsdbLOGICAL HOSTS IN MAINTENANCE STATE NoneSTATUS OF PRIVATE NETS IN THE CLUSTER Status of Interconnects on fsmsdb1: interconnect0: selected interconnect1: up Status of private nets on fsmsdb1: To fsmsdb1 - UP To fsmsdb2 - UP Status of Interconnects on fsmsdb2: interconnect0: selected interconnect1: up Status of private nets on fsmsdb2: To fsmsdb1 - UP To fsmsdb2 - UPSTATUS OF PUBLIC NETS IN THE CLUSTERStatus of Public Network On fsmsdb1:bkggrp r_adp status fo_time live_adpnafo0 hme1:hme3 OK NEVER hme1Status of Public Network On fsmsdb2:bkggrp r_adp status fo_time live_adpnafo0 hme1:hme3 OK NEVER hme1STATUS OF DATA SERVICES RUNNING IN THE CLUSTERStatus Of Registered Data Services sybase: On nfs: OffStatus Of Data Services Running On fsmsdb1 Data Service "sybase": Database Status on fsmsdb1: SYBASE_BAK - running; smsserver - running; Status Of Data Services Running On fsmsdb2 Data Service "sybase": Not being managed on this systemRECENT ERROR MESSAGES FROM THE CLUSTERRecent Error Messages on fsmsdb1Jun 12 03:02:13 fsmsdb1 unix: NFS server backupserver okJun 15 14:57:59 fsmsdb1 su: 'su root' failed for sybase on /dev/pts/0Jun 15 14:58:08 fsmsdb1 last message repeated 1 timeJun 26 02:00:10 fsmsdb1 unix: NFS server backupserver not responding still tryingJun 26 03:23:39 fsmsdb1 unix: NFS server backupserver okJun 29 11:57:08 fsmsdb1 explorer: Explorer startedJun 29 12:03:42 fsmsdb1 explorer: Explorer finishedRecent Error Messages on fsmsdb2Jun 29 12:25:19 fsmsdb2 unix: pseudo-device: lockstat0Jun 29 12:25:19 fsmsdb2 unix: lockstat0 is /pseudo/lockstat@0Jun 29 12:26:36 fsmsdb2 unix: WARNING: /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2200002037c85404,0 (ssd8):^M^MJun 29 12:26:36 fsmsdb2 unix: transport rejected (-2)^M^MJun 29 12:26:47 fsmsdb2 unix: Vendor 'SEAGATE', product 'ST318304FSUN18G', (unknown capacity)^MJun 29 12:28:36 fsmsdb2 last message repeated 8 timesJun 29 12:29:12 fsmsdb2 explorer: Explorer finished
# formatSearching for disks...doneAVAILABLE DISK SELECTIONS: 0. c0t0d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c85404,0 1. c0t5d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0 2. c0t10d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0 3. c0t16d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0 4. c0t19d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0 5. c0t26d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0 6. c2t0d0 /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0 7. c2t2d0 /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0 8. c3t65d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0 9. c3t69d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0 10. c3t74d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0 11. c3t80d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0 12. c3t84d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0 13. c3t86d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0 14. c3t90d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0Specify disk (enter its number): ^D
# iostat -Enc1t6d0 Soft Errors: 0 Hard Errors: 4 Transport Errors: 0 Vendor: TOSHIBA Product: DVD-ROM SD-M1401 Revision: 1007 Serial No: 06/22/00 RPM: 0 Heads: 0 Size: 18446744073.71GB <-8589934591 bytes>Media Error: 0 Device Not Ready: 3 No Device: 1 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c2t2d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0101L08R9T RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c2t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0108L0AG1B RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c0t10d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L07FTE RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c0t26d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0044L069NG RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c0t5d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L080EX RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c0t19d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0047L07HMS RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c0t16d0 Soft Errors: 0 Hard Errors: 1 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0044L062MP RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c0t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 34 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0046L06SNX RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t69d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L08BYB RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t84d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0101L08S00 RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t90d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0101L08R9D RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t86d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L08ETM RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t80d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0050L08EEY RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t74d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 042D Serial No: 0046L06PDB RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 c3t65d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST318304FSUN18G Revision: 0726 Serial No: 0131L0AQ60 RPM: 7200 Heads: 19 Size: 18.11GB <18110967808 bytes>Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0 rmt/0 Soft Errors: 578 Hard Errors: 20 Transport Errors: 0 Vendor: HP Product: C1537A Revision: L706 Serial No: 62
# scconf fsms -pChecking node status...Current Configuration for Cluster fsms Hosts in cluster: fsmsdb1 fsmsdb2 Private Network Interfaces for fsmsdb1: hme0 hme2 fsmsdb2: hme0 hme2 Quorum Device InformationQuorum device for hosts fsmsdb1 and fsmsdb2: 0046L06SNX //通过format和iostat命令可以看出坏的磁盘刚好是Quorum device磁盘 Logical Host Timeout Value : Step10 :720 Step11 :720 Logical Host :180Logical Host : fsmsdb Node List : fsmsdb1 fsmsdb2 Disk Groups : fsmsdg Logical Address : fsmsdb Logical Interface : 1 Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2) Automatic Switchover : no
# vxdisk listDEVICE TYPE DISK GROUP STATUSc0t0d0s2 sliced - - errorc0t5d0s2 sliced dm_c0t5d0 fsmsdg onlinec0t10d0s2 sliced dm_c0t10d0 fsmsdg onlinec0t16d0s2 sliced dm_c0t16d0 fsmsdg onlinec0t19d0s2 sliced dm_c0t19d0 fsmsdg onlinec0t26d0s2 sliced - - errorc2t0d0s2 sliced - - errorc2t0d0s7 simple c2t0d0s7 rootdg onlinec2t2d0s2 sliced - - errorc3t65d0s2 sliced dm_c3t65d0 fsmsdg onlinec3t69d0s2 sliced dm_c3t69d0 fsmsdg onlinec3t74d0s2 sliced dm_c3t74d0 fsmsdg onlinec3t80d0s2 sliced dm_c3t80d0 fsmsdg onlinec3t84d0s2 sliced dm_c3t84d0 fsmsdg onlinec3t86d0s2 sliced - - errorc3t90d0s2 sliced - - error- - dm_c0t0d0 fsmsdg failed was:c0t0d0s2
# vxprint -htDisk group: rootdgDG NAME NCONFIG NLOG MINORS GROUP-IDDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODESD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODESV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODEdg rootdg default default 0 993346192.1026.fsmsdb1dm c2t0d0s7 c2t0d0s7 simple 1024 74367 -Disk group: fsmsdgDG NAME NCONFIG NLOG MINORS GROUP-IDDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODESD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODESV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODEdg fsmsdg default default 51000 989998066.1084.fsmsdb1dm dm_c0t0d0 - - - - NODEVICEdm dm_c0t5d0 c0t5d0s2 sliced 4711 35363560 -dm dm_c0t10d0 c0t10d0s2 sliced 4711 35363560 -dm dm_c0t16d0 c0t16d0s2 sliced 4711 35363560 -dm dm_c0t19d0 c0t19d0s2 sliced 4711 35363560 -dm dm_c3t65d0 c3t65d0s2 sliced 4711 35363560 -dm dm_c3t69d0 c3t69d0s2 sliced 4711 35363560 -dm dm_c3t74d0 c3t74d0s2 sliced 4711 35363560 -dm dm_c3t80d0 c3t80d0s2 sliced 4711 35363560 -dm dm_c3t84d0 c3t84d0s2 sliced 4711 35363560 -。。。v lv_fsmsdb4 gen ENABLED ACTIVE 8388608 SELECT -pl lv_fsmsdb4-01 lv_fsmsdb4 DISABLED NODEVICE 8392072 CONCAT - RWsd dm_c0t0d0-06 lv_fsmsdb4-01 dm_c0t0d0 25694536 8392072 0 - RLOCpl lv_fsmsdb4-02 lv_fsmsdb4 ENABLED ACTIVE 8392072 CONCAT - RWsd dm_c0t10d0-05 lv_fsmsdb4-02 dm_c0t10d0 33568288 1795272 0 c0t10d0 ENAsd dm_c0t16d0-05 lv_fsmsdb4-02 dm_c0t16d0 33568288 1795272 1795272 c0t16d0 ENAsd dm_c3t69d0-05 lv_fsmsdb4-02 dm_c3t69d0 33568288 1795272 3590544 c3t69d0 ENAsd dm_c0t5d0-07 lv_fsmsdb4-02 dm_c0t5d0 33883992 212040 5385816 c0t5d0 ENAsd dm_c3t65d0-04 lv_fsmsdb4-02 dm_c3t65d0 16788856 1583232 5597856 c3t65d0 ENAsd dm_c3t84d0-05 lv_fsmsdb4-02 dm_c3t84d0 33568288 1210984 7181088 c3t84d0 ENA。。。
# luxadm probeFound Enclosure(s):SENA Name:A1C0 Node WWN:50800200000ea490 Logical Path:/dev/es/ses0 Logical Path:/dev/es/ses1SENA Name:A2C3 Node WWN:50800200000ead38 Logical Path:/dev/es/ses2 Logical Path:/dev/es/ses3Found Fibre Channel device(s): Node WWN:2000002037d89d9a Device Type:Disk device Logical Path:/dev/rdsk/c2t2d0s2 Node WWN:2000002037e493db Device Type:Disk device Logical Path:/dev/rdsk/c2t0d0s2 # luxadm display 50800200000ea490 SENA DISK STATUS SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)0 On (Bypassed:AB) On (O.K.) 2000002037c3b5a71 Not Installed Not Installed 2 Not Installed Not Installed 3 Not Installed On (O.K.) 2000002037c89c7b4 Not Installed Not Installed 5 On (O.K.) 2000002037d80498 Not Installed 6 Not Installed On (O.K.) 2000002037c54d3d 7 Not Installed Not Installed 8 Not Installed Not Installed 9 Not Installed Not Installed 10 On (O.K.) 2000002037d803f1 On (O.K.) 2000002037c3bf4f SUBSYSTEM STATUSFW Revision:1.09 Box ID:0 Node WWN:50800200000ea490 Enclosure Name:A1C0Power Supplies (0,2 in front, 1 in rear) 0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)Fans (0 in front, 1 in rear) 0 O.K.(rev.-04) 1 O.K.(rev.-00)ESI Interface board(IB) (A top, B bottom) A: O.K.(rev.-04) GBIC module (1 on left, 0 on right in IB) 0 O.K.(mod.-05) 1 Not Installed B: O.K.(rev.-04) GBIC module (1 on left, 0 on right in IB) 0 O.K.(mod.-05) 1 Not InstalledDisk backplane (0 in front, 1 in rear) Front Backplane: O.K.(rev.-04) Temperature sensors (on front backplane) 0:36篊 1:36篊 2:34篊 3:34篊 4:34篊 5:36篊 6:36篊 7:34篊 8:36篊 9:36篊 10:36篊 (All temperatures are NORMAL.) Rear Backplane: O.K.(rev.-04) Temperature sensors (on rear backplane) 0:36篊 1:36篊 2:36篊 3:36篊 4:36篊 5:34篊 6:36篊 7:34篊 8:34篊 9:34篊 10:34篊 (All temperatures are NORMAL.)Interconnect assembly O.K.(rev.-02)Loop configuration Loop A is configured as a single loop. Loop B is configured as a single loop.Language USA English
# luxadm display 50800200000ead38 SENA DISK STATUS SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)0 Not Installed On (O.K.) 2000002037d83bf41 On (O.K.) 2000002037ba26b8 Not Installed 2 Not Installed Not Installed 3 Not Installed Not Installed 4 Not Installed On (O.K.) 2000002037d89c415 On (O.K.) 2000002037d84870 Not Installed 6 Not Installed On (O.K.) 2000002037d83b937 Not Installed Not Installed 8 Not Installed Not Installed 9 Not Installed Not Installed 10 On (O.K.) 2000002037c8546b On (O.K.) 2000002037d8992a SUBSYSTEM STATUSFW Revision:1.09 Box ID:2 Node WWN:50800200000ead38 Enclosure Name:A2C3Power Supplies (0,2 in front, 1 in rear) 0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)Fans (0 in front, 1 in rear) 0 O.K.(rev.-04) 1 O.K.(rev.-00)ESI Interface board(IB) (A top, B bottom) A: O.K.(rev.-04) GBIC module (1 on left, 0 on right in IB) 0 O.K.(mod.-05) 1 Not Installed B: O.K.(rev.-04) GBIC module (1 on left, 0 on right in IB) 0 O.K.(mod.-05) 1 Not InstalledDisk backplane (0 in front, 1 in rear) Front Backplane: O.K.(rev.-04) Temperature sensors (on front backplane) 0:36篊 1:36篊 2:36篊 3:36篊 4:34篊 5:36篊 6:36篊 7:34篊 8:34篊 9:36篊 10:36篊 (All temperatures are NORMAL.) Rear Backplane: O.K.(rev.-04) Temperature sensors (on rear backplane) 0:37篊 1:37篊 2:36篊 3:36篊 4:36篊 5:36篊 6:37篊 7:36篊 8:36篊 9:36篊 10:36篊 (All temperatures are NORMAL.)Interconnect assembly O.K.(rev.-02)Loop configuration Loop A is configured as a single loop. Loop B is configured as a single loop.Language USA English
# scconf fsms -q fsmsdb1 fsmsdb2Checking node status...Checking host fsmsdb2 ...fsmsdb2 is aliveGetting device information for hosts fsmsdb1 and fsmsdb2This may take a few seconds to a few minutes...doneSelect quorum device for fsmsdb1 and fsmsdb2.Type the number corresponding to the desired selection.For example: 1 1) DISK:c0t10d0s2:0050L07FTE 2) DISK:c0t16d0s2:0044L062MP 3) DISK:c0t19d0s2:0047L07HMS 4) DISK:c0t26d0s2:0044L069NG 5) DISK:c0t5d0s2:0050L080EX 6) DISK:c3t65d0s2:0131L0AQ60 7) DISK:c3t69d0s2:0050L08BYB 8) DISK:c3t74d0s2:0046L06PDB 9) DISK:c3t80d0s2:0050L08EEY10) DISK:c3t84d0s2:0101L08S0011) DISK:c3t86d0s2:0050L08ETM12) DISK:c3t90d0s2:0101L08R9DQuorum device: 1Disk c0t10d0s2 with serial id 0050L07FTE has been chosenas the quorum device.
# scconf fsms -pChecking node status...Current Configuration for Cluster fsms Hosts in cluster: fsmsdb1 fsmsdb2 Private Network Interfaces for fsmsdb1: hme0 hme2 fsmsdb2: hme0 hme2 Quorum Device InformationQuorum device for hosts fsmsdb1 and fsmsdb2: 0050L07FTE Logical Host Timeout Value : Step10 :720 Step11 :720 Logical Host :180Logical Host : fsmsdb Node List : fsmsdb1 fsmsdb2 Disk Groups : fsmsdg Logical Address : fsmsdb Logical Interface : 1 Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2) Automatic Switchover : no
# rlogin fsmsdb2Last login: Fri Jun 29 14:18:26 from fsmsdb1Sun Microsystems Inc. SunOS 5.6 Generic August 1997 # scconf fsms -pChecking node status...Current Configuration for Cluster fsms Hosts in cluster: fsmsdb1 fsmsdb2 Private Network Interfaces for fsmsdb1: hme0 hme2 fsmsdb2: hme0 hme2 Quorum Device InformationQuorum device for hosts fsmsdb1 and fsmsdb2: 0046L06SNX Logical Host Timeout Value : Step10 :720 Step11 :720 Logical Host :180Logical Host : fsmsdb Node List : fsmsdb1 fsmsdb2 Disk Groups : fsmsdg Logical Address : fsmsdb Logical Interface : 1 Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2) Automatic Switchover : no # scconf fsms -q fsmsdb1 fsmsdb2Checking node status...Checking host fsmsdb1 ...fsmsdb1 is aliveGetting device information for hosts fsmsdb1 and fsmsdb2This may take a few seconds to a few minutes...doneSelect quorum device for fsmsdb1 and fsmsdb2.Type the number corresponding to the desired selection.For example: 1 1) DISK:c0t10d0s2:0050L07FTE 2) DISK:c0t16d0s2:0044L062MP 3) DISK:c0t19d0s2:0047L07HMS 4) DISK:c0t26d0s2:0044L069NG 5) DISK:c0t5d0s2:0050L080EX 6) DISK:c3t65d0s2:0131L0AQ60 7) DISK:c3t69d0s2:0050L08BYB 8) DISK:c3t74d0s2:0046L06PDB 9) DISK:c3t80d0s2:0050L08EEY10) DISK:c3t84d0s2:0101L08S0011) DISK:c3t86d0s2:0050L08ETM12) DISK:c3t90d0s2:0101L08R9DQuorum device: 1Disk c0t10d0s2 with serial id 0050L07FTE has been chosenas the quorum device. # scconf fsms -pChecking node status...Current Configuration for Cluster fsms Hosts in cluster: fsmsdb1 fsmsdb2 Private Network Interfaces for fsmsdb1: hme0 hme2 fsmsdb2: hme0 hme2 Quorum Device InformationQuorum device for hosts fsmsdb1 and fsmsdb2: 0050L07FTE Logical Host Timeout Value : Step10 :720 Step11 :720 Logical Host :180Logical Host : fsmsdb Node List : fsmsdb1 fsmsdb2 Disk Groups : fsmsdg Logical Address : fsmsdb Logical Interface : 1 Network Interface : hme1 (fsmsdb1) hme1 (fsmsdb2) Automatic Switchover : no
# vxdiskadmVolume Manager Support OperationsMenu: VolumeManager/Disk 1 Add or initialize one or more disks 2 Encapsulate one or more disks 3 Remove a disk 4 Remove a disk for replacement 5 Replace a failed or removed disk 6 Mirror volumes on a disk 7 Move volumes from a disk 8 Enable access to (import) a disk group 9 Remove access to (deport) a disk group 10 Enable (online) a disk device 11 Disable (offline) a disk device 12 Mark a disk as a spare for a disk group 13 Turn off the spare flag on a disk list List disk information ? Display help about menu ?? Display help about the menuing system q Exit from menusSelect an operation to perform: 4Remove a disk for replacementMenu: VolumeManager/Disk/RemoveForReplace Use this menu operation to remove a physical disk from a disk group, while retaining the disk name. This changes the state for the disk name to a "removed" disk. If there are any initialized disks that are not part of a disk group, you will be given the option of using one of these disks as a replacement.Enter disk name [,list,q,?] listDisk group: rootdgDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEdm c2t0d0s7 c2t0d0s7 simple 1024 74367 -Disk group: fsmsdgDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEdm dm_c0t0d0 - - - - NODEVICEdm dm_c0t5d0 c0t5d0s2 sliced 4711 35363560 -dm dm_c0t10d0 c0t10d0s2 sliced 4711 35363560 -dm dm_c0t16d0 c0t16d0s2 sliced 4711 35363560 -dm dm_c0t19d0 c0t19d0s2 sliced 4711 35363560 -dm dm_c3t65d0 c3t65d0s2 sliced 4711 35363560 -dm dm_c3t69d0 c3t69d0s2 sliced 4711 35363560 -dm dm_c3t74d0 c3t74d0s2 sliced 4711 35363560 -dm dm_c3t80d0 c3t80d0s2 sliced 4711 35363560 -dm dm_c3t84d0 c3t84d0s2 sliced 4711 35363560 -Enter disk name [,list,q,?] dm_c0t0d0 The following volumes will lose mirrors as a result of this operation: fsmsdg-stat lv_fsmsdb1 lv_fsmsdb10 lv_fsmsdb11 lv_fsmsdb12 lv_fsmsdb13 lv_fsmsdb14 lv_fsmsdb15 lv_fsmsdb16 lv_fsmsdb2 lv_fsmsdb3 lv_fsmsdb4 lv_fsmsdb5 lv_fsmsdb6 lv_fsmsdb7 lv_fsmsdb8 lv_fsmsdb9 lv_fsmsdbfs lv_mdbs lv_mlogdbs No data on these volumes will be lost. The requested operation is to remove disk dm_c0t0d0 from disk group fsmsdg. The disk name will be kept, along with any volumes using the disk, allowing replacement of the disk. Select "Replace a failed or removed disk" from the main menu when you wish to replace the disk.Continue with operation? [y,n,q,?] (default: y) y Removal of disk dm_c0t0d0 completed successfully.Remove another disk? [y,n,q,?] (default: n) nVolume Manager Support OperationsMenu: VolumeManager/Disk 1 Add or initialize one or more disks 2 Encapsulate one or more disks 3 Remove a disk 4 Remove a disk for replacement 5 Replace a failed or removed disk 6 Mirror volumes on a disk 7 Move volumes from a disk 8 Enable access to (import) a disk group 9 Remove access to (deport) a disk group 10 Enable (online) a disk device 11 Disable (offline) a disk device 12 Mark a disk as a spare for a disk group 13 Turn off the spare flag on a disk list List disk information ? Display help about menu ?? Display help about the menuing system q Exit from menusSelect an operation to perform: 11Disable (offline) a disk deviceMenu: VolumeManager/Disk/OfflineDisk Use this menu operation to disable all access to a disk device by the Volume Manager. This operation can be applied only to disks that are not currently in a disk group. Use this operation if you intend to remove a disk from a system without rebooting. NOTE: Many systems do not support disks that can be removed from a system during normal operation. On such systems, the offline operation is seldom useful.Select a disk device to disable [,list,q,?] listDEVICE DISK GROUP STATUSc0t0d0 - - errorc0t5d0 dm_c0t5d0 fsmsdg onlinec0t10d0 dm_c0t10d0 fsmsdg onlinec0t16d0 dm_c0t16d0 fsmsdg onlinec0t19d0 dm_c0t19d0 fsmsdg onlinec0t26d0 - - errorc2t0d0 - - errorc2t0d0 c2t0d0s7 rootdg onlinec2t2d0 - - errorc3t65d0 dm_c3t65d0 fsmsdg onlinec3t69d0 dm_c3t69d0 fsmsdg onlinec3t74d0 dm_c3t74d0 fsmsdg onlinec3t80d0 dm_c3t80d0 fsmsdg onlinec3t84d0 dm_c3t84d0 fsmsdg onlinec3t86d0 - - errorc3t90d0 - - errorSelect a disk device to disable [,list,q,?] c0t0d0Disable another device? [y,n,q,?] (default: n) Volume Manager Support OperationsMenu: VolumeManager/Disk 1 Add or initialize one or more disks 2 Encapsulate one or more disks 3 Remove a disk 4 Remove a disk for replacement 5 Replace a failed or removed disk 6 Mirror volumes on a disk 7 Move volumes from a disk 8 Enable access to (import) a disk group 9 Remove access to (deport) a disk group 10 Enable (online) a disk device 11 Disable (offline) a disk device 12 Mark a disk as a spare for a disk group 13 Turn off the spare flag on a disk list List disk information ? Display help about menu ?? Display help about the menuing system q Exit from menusSelect an operation to perform: q # vxprint -htDisk group: rootdgDG NAME NCONFIG NLOG MINORS GROUP-IDDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODESD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODESV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODEdg rootdg default default 0 993346192.1026.fsmsdb1dm c2t0d0s7 c2t0d0s7 simple 1024 74367 -Disk group: fsmsdgDG NAME NCONFIG NLOG MINORS GROUP-IDDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODESD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODESV NAME PLEX VOLNAME NVOLLAYR LENGTH [COL/]OFF AM/NM MODEdg fsmsdg default default 51000 989998066.1084.fsmsdb1dm dm_c0t0d0 - - - - REMOVEDdm dm_c0t5d0 c0t5d0s2 sliced 4711 35363560 -dm dm_c0t10d0 c0t10d0s2 sliced 4711 35363560 -dm dm_c0t16d0 c0t16d0s2 sliced 4711 35363560 -dm dm_c0t19d0 c0t19d0s2 sliced 4711 35363560 -dm dm_c3t65d0 c3t65d0s2 sliced 4711 35363560 -dm dm_c3t69d0 c3t69d0s2 sliced 4711 35363560 -dm dm_c3t74d0 c3t74d0s2 sliced 4711 35363560 -dm dm_c3t80d0 c3t80d0s2 sliced 4711 35363560 -dm dm_c3t84d0 c3t84d0s2 sliced 4711 35363560 -。。。v lv_fsmsdb4 gen ENABLED ACTIVE 8388608 SELECT -pl lv_fsmsdb4-01 lv_fsmsdb4 DISABLED REMOVED 8392072 CONCAT - RWsd dm_c0t0d0-06 lv_fsmsdb4-01 dm_c0t0d0 25694536 8392072 0 - RLOCpl lv_fsmsdb4-02 lv_fsmsdb4 ENABLED ACTIVE 8392072 CONCAT - RWsd dm_c0t10d0-05 lv_fsmsdb4-02 dm_c0t10d0 33568288 1795272 0 c0t10d0 ENAsd dm_c0t16d0-05 lv_fsmsdb4-02 dm_c0t16d0 33568288 1795272 1795272 c0t16d0 ENAsd dm_c3t69d0-05 lv_fsmsdb4-02 dm_c3t69d0 33568288 1795272 3590544 c3t69d0 ENAsd dm_c0t5d0-07 lv_fsmsdb4-02 dm_c0t5d0 33883992 212040 5385816 c0t5d0 ENAsd dm_c3t65d0-04 lv_fsmsdb4-02 dm_c3t65d0 16788856 1583232 5597856 c3t65d0 ENAsd dm_c3t84d0-05 lv_fsmsdb4-02 dm_c3t84d0 33568288 1210984 7181088 c3t84d0 ENA。。。 # vxdisk listDEVICE TYPE DISK GROUP STATUSc0t0d0s2 sliced - - offlinec0t5d0s2 sliced dm_c0t5d0 fsmsdg onlinec0t10d0s2 sliced dm_c0t10d0 fsmsdg onlinec0t16d0s2 sliced dm_c0t16d0 fsmsdg onlinec0t19d0s2 sliced dm_c0t19d0 fsmsdg onlinec0t26d0s2 sliced - - errorc2t0d0s2 sliced - - errorc2t0d0s7 simple c2t0d0s7 rootdg onlinec2t2d0s2 sliced - - errorc3t65d0s2 sliced dm_c3t65d0 fsmsdg onlinec3t69d0s2 sliced dm_c3t69d0 fsmsdg onlinec3t74d0s2 sliced dm_c3t74d0 fsmsdg onlinec3t80d0s2 sliced dm_c3t80d0 fsmsdg onlinec3t84d0s2 sliced dm_c3t84d0 fsmsdg onlinec3t86d0s2 sliced - - errorc3t90d0s2 sliced - - error- - dm_c0t0d0 fsmsdg removed was:c0t0d0s2
# luxadm remove_device -F /dev/rdsk/c0t0d0s2 WARNING!!! Please ensure that no filesystems are mounted on these device(s). All data on these devices should have been backed up.Inquiry failed for /devices/sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c85404,0:c,raw # luxadm remove_device -F A1C0,f0 WARNING!!! Please ensure that no filesystems are mounted on these device(s). All data on these devices should have been backed up.A1C0,f0 is bypassed (Port:AB). Could not get device specific information.
# luxadm insert_device A1C0,f0Notice: A1C0,f0 may already be present.The list of devices which will be inserted is: 1: Box Name: "A1C0" front slot 0Please verify the above list of devices andthen enter 'c' or to Continue or 'q' to Quit. [Default: c]: Hit after inserting the device(s). Drive in Box Name "A1C0" front slot 0 Logical Nodes under /dev/dsk and /dev/rdsk : c0t0d0s0 c0t0d0s1 c0t0d0s2 c0t0d0s3 c0t0d0s4 c0t0d0s5 c0t0d0s6 c0t0d0s7
# luxadm display 50800200000ea490 SENA DISK STATUS SLOT FRONT DISKS (Node WWN) REAR DISKS (Node WWN)0 On (O.K.) 200000203788ecc0 On (O.K.) 2000002037c3b5a71 Not Installed Not Installed 2 Not Installed Not Installed 3 Not Installed On (O.K.) 2000002037c89c7b4 Not Installed Not Installed 5 On (O.K.) 2000002037d80498 Not Installed 6 Not Installed On (Bypassed:AB) 7 Not Installed Not Installed 8 Not Installed Not Installed 9 Not Installed Not Installed 10 On (O.K.) 2000002037d803f1 On (O.K.) 2000002037c3bf4f SUBSYSTEM STATUSFW Revision:1.09 Box ID:0 Node WWN:50800200000ea490 Enclosure Name:A1C0Power Supplies (0,2 in front, 1 in rear) 0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)Fans (0 in front, 1 in rear) 0 O.K.(rev.-04) 1 O.K.(rev.-00)ESI Interface board(IB) (A top, B bottom) A: O.K.(rev.-04) GBIC module (1 on left, 0 on right in IB) 0 O.K.(mod.-05) 1 Not Installed B: O.K.(rev.-04) GBIC module (1 on left, 0 on right in IB) 0 O.K.(mod.-05) 1 Not InstalledDisk backplane (0 in front, 1 in rear) Front Backplane: O.K.(rev.-04) Temperature sensors (on front backplane) 0:36篊 1:36篊 2:34篊 3:34篊 4:34篊 5:36篊 6:36篊 7:34篊 8:36篊 9:36篊 10:36篊 (All temperatures are NORMAL.) Rear Backplane: O.K.(rev.-04) Temperature sensors (on rear backplane) 0:36篊 1:36篊 2:36篊 3:36篊 4:36篊 5:34篊 6:36篊 7:34篊 8:34篊 9:36篊 10:34篊 (All temperatures are NORMAL.)Interconnect assembly O.K.(rev.-02)Loop configuration Loop A is configured as a single loop. Loop B is configured as a single loop.Language USA English # # drvconfig;disks # formatSearching for disks...doneAVAILABLE DISK SELECTIONS: 0. c0t0d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w210000203788ecc0,0 1. c0t5d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0 2. c0t10d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0 3. c0t16d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0 4. c0t19d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0 5. c0t26d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0 6. c2t0d0 /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0 7. c2t2d0 /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0 8. c3t65d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0 9. c3t69d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0 10. c3t74d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0 11. c3t80d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0 12. c3t84d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0 13. c3t86d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0 14. c3t90d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0Specify disk (enter its number): ^D
# vxdisksetup -i c0t0d0vxvm:vxdisk: ERROR: Device c0t0d0s2: online failed: Device path not valid # vxdisk listDEVICE TYPE DISK GROUP STATUSc0t0d0s2 sliced - - errorc0t5d0s2 sliced dm_c0t5d0 fsmsdg onlinec0t10d0s2 sliced dm_c0t10d0 fsmsdg onlinec0t16d0s2 sliced dm_c0t16d0 fsmsdg onlinec0t19d0s2 sliced dm_c0t19d0 fsmsdg onlinec0t26d0s2 sliced - - errorc2t0d0s2 sliced - - errorc2t0d0s7 simple c2t0d0s7 rootdg onlinec2t2d0s2 sliced - - errorc3t65d0s2 sliced dm_c3t65d0 fsmsdg onlinec3t69d0s2 sliced dm_c3t69d0 fsmsdg onlinec3t74d0s2 sliced dm_c3t74d0 fsmsdg onlinec3t80d0s2 sliced dm_c3t80d0 fsmsdg onlinec3t84d0s2 sliced dm_c3t84d0 fsmsdg onlinec3t86d0s2 sliced - - errorc3t90d0s2 sliced - - error- - dm_c0t0d0 fsmsdg removed was:c0t0d0s2 # vxdiskadmVolume Manager Support OperationsMenu: VolumeManager/Disk 1 Add or initialize one or more disks 2 Encapsulate one or more disks 3 Remove a disk 4 Remove a disk for replacement 5 Replace a failed or removed disk 6 Mirror volumes on a disk 7 Move volumes from a disk 8 Enable access to (import) a disk group 9 Remove access to (deport) a disk group 10 Enable (online) a disk device 11 Disable (offline) a disk device 12 Mark a disk as a spare for a disk group 13 Turn off the spare flag on a disk list List disk information ? Display help about menu ?? Display help about the menuing system q Exit from menusSelect an operation to perform: 10Enable (online) a disk deviceMenu: VolumeManager/Disk/OnlineDisk Use this operation to enable access to a disk that was disabled with the "Disable (offline) a disk device" operation. You can also use this operation to re-scan a disk that may have been changed outside of the Volume Manager. For example, If a disk is shared between two systems, the Volume Manager running on the other system may have changed the disk. If so, you can use this operation to re-scan the disk. NOTE: Many voldiskadm operations re-scan disks without user intervention. This will eliminate most needs to online a disk directly, except when the disk is directly offlined.Select a disk device to enable [,list,q,?] listDEVICE DISK GROUP STATUSc0t0d0 - - errorc0t5d0 dm_c0t5d0 fsmsdg onlinec0t10d0 dm_c0t10d0 fsmsdg onlinec0t16d0 dm_c0t16d0 fsmsdg onlinec0t19d0 dm_c0t19d0 fsmsdg onlinec0t26d0 - - errorc2t0d0 - - errorc2t0d0 c2t0d0s7 rootdg onlinec2t2d0 - - errorc3t65d0 dm_c3t65d0 fsmsdg onlinec3t69d0 dm_c3t69d0 fsmsdg onlinec3t74d0 dm_c3t74d0 fsmsdg onlinec3t80d0 dm_c3t80d0 fsmsdg onlinec3t84d0 dm_c3t84d0 fsmsdg onlinec3t86d0 - - errorc3t90d0 - - errorSelect a disk device to enable [,list,q,?] c0t0d0 vxvm:vxdisk: ERROR: Device c0t0d0s2: online failed: Device path not validEnable another device? [y,n,q,?] (default: n) Volume Manager Support OperationsMenu: VolumeManager/Disk 1 Add or initialize one or more disks 2 Encapsulate one or more disks 3 Remove a disk 4 Remove a disk for replacement 5 Replace a failed or removed disk 6 Mirror volumes on a disk 7 Move volumes from a disk 8 Enable access to (import) a disk group 9 Remove access to (deport) a disk group 10 Enable (online) a disk device 11 Disable (offline) a disk device 12 Mark a disk as a spare for a disk group 13 Turn off the spare flag on a disk list List disk information ? Display help about menu ?? Display help about the menuing system q Exit from menusSelect an operation to perform: 5Replace a failed or removed diskMenu: VolumeManager/Disk/ReplaceDisk Use this menu operation to specify a replacement disk for a disk that you removed with the "Remove a disk for replacement" menu operation, or that failed during use. You will be prompted for a disk name to replace and a disk device to use as a replacement. You can choose an uninitialized disk, in which case the disk will be initialized, or you can choose a disk that you have already initialized using the Add or initialize a disk menu operation.Select a removed or failed disk [,list,q,?] listDisk group: rootdgDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEDisk group: fsmsdgDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEdm dm_c0t0d0 - - - - REMOVEDSelect a removed or failed disk [,list,q,?] dm_c0t0d0Select disk device to initialize [,list,q,?] listDEVICE DISK GROUP STATUSc0t0d0 - - errorc0t5d0 dm_c0t5d0 fsmsdg onlinec0t10d0 dm_c0t10d0 fsmsdg onlinec0t16d0 dm_c0t16d0 fsmsdg onlinec0t19d0 dm_c0t19d0 fsmsdg onlinec0t26d0 - - errorc2t0d0 - - errorc2t0d0 c2t0d0s7 rootdg onlinec2t2d0 - - errorc3t65d0 dm_c3t65d0 fsmsdg onlinec3t69d0 dm_c3t69d0 fsmsdg onlinec3t74d0 dm_c3t74d0 fsmsdg onlinec3t80d0 dm_c3t80d0 fsmsdg onlinec3t84d0 dm_c3t84d0 fsmsdg onlinec3t86d0 - - errorc3t90d0 - - errorSelect disk device to initialize [,list,q,?] c0t0d0 The following disk device has a valid VTOC, but does not appear to have been initialized for the Volume Manager. If there is data on the disk that should NOT be destroyed you should encapsulate the existing disk partitions as volumes instead of adding the disk as a new disk. Output format: [Device_Name] c0t0d0Encapsulate this device? [y,n,q,?] (default: y) Select a different device? [y,n,q,?] (default: n) Replace a different disk? [y,n,q,?] (default: n) Volume Manager Support OperationsMenu: VolumeManager/Disk 1 Add or initialize one or more disks 2 Encapsulate one or more disks 3 Remove a disk 4 Remove a disk for replacement 5 Replace a failed or removed disk 6 Mirror volumes on a disk 7 Move volumes from a disk 8 Enable access to (import) a disk group 9 Remove access to (deport) a disk group 10 Enable (online) a disk device 11 Disable (offline) a disk device 12 Mark a disk as a spare for a disk group 13 Turn off the spare flag on a disk list List disk information ? Display help about menu ?? Display help about the menuing system q Exit from menusSelect an operation to perform: qGoodbye. # vxdisk listDEVICE TYPE DISK GROUP STATUSc0t0d0s2 sliced - - errorc0t5d0s2 sliced dm_c0t5d0 fsmsdg onlinec0t10d0s2 sliced dm_c0t10d0 fsmsdg onlinec0t16d0s2 sliced dm_c0t16d0 fsmsdg onlinec0t19d0s2 sliced dm_c0t19d0 fsmsdg onlinec0t26d0s2 sliced - - errorc2t0d0s2 sliced - - errorc2t0d0s7 simple c2t0d0s7 rootdg onlinec2t2d0s2 sliced - - errorc3t65d0s2 sliced dm_c3t65d0 fsmsdg onlinec3t69d0s2 sliced dm_c3t69d0 fsmsdg onlinec3t74d0s2 sliced dm_c3t74d0 fsmsdg onlinec3t80d0s2 sliced dm_c3t80d0 fsmsdg onlinec3t84d0s2 sliced dm_c3t84d0 fsmsdg onlinec3t86d0s2 sliced - - errorc3t90d0s2 sliced - - error- - dm_c0t0d0 fsmsdg removed was:c0t0d0s2 # formatSearching for disks...doneAVAILABLE DISK SELECTIONS: 0. c0t0d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w210000203788ecc0,0 1. c0t5d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d80498,0 2. c0t10d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d803f1,0 3. c0t16d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3b5a7,0 4. c0t19d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c89c7b,0 5. c0t26d0 /sbus@2,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037c3bf4f,0 6. c2t0d0 /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037e493db,0 7. c2t2d0 /sbus@6,0/SUNW,socal@d,10000/sf@0,0/ssd@w2100002037d89d9a,0 8. c3t65d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037ba26b8,0 9. c3t69d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d84870,0 10. c3t74d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037c8546b,0 11. c3t80d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83bf4,0 12. c3t84d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d89c41,0 13. c3t86d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d83b93,0 14. c3t90d0 /sbus@6,0/SUNW,socal@d,10000/sf@1,0/ssd@w2100002037d8992a,0Specify disk (enter its number): 0selecting c0t0d0[disk formatted]FORMAT MENU: disk - select a disk type - select (define) a disk type partition - select (define) a partition table current - describe the current disk format - format and analyze the disk repair - repair a defective sector label - write label to the disk analyze - surface analysis defect - defect list management backup - search for backup labels verify - read and display labels save - save new disk/partition definitions inquiry - show vendor, product and revision volname - set 8-character volume name ! - execute , then return quitformat> verPrimary label contents:Volume name = < >ascii name = pcyl = 7508ncyl = 7506acyl = 2nhead = 19nsect = 248
向AI问一下细节
推荐阅读:
IBM Aix系统 rootvg 镜像卷更换坏硬盘步骤
windows下,ruby环境的安装,与sass,compass的使用方法
免责声明:本站发布的内容(图片、视频和文字)以原创、转载和分享为主,文章观点不代表本网站立场,如果涉及侵权请联系站长邮箱:is@yisu.com进行举报,并提供相关证据,一经查实,将立刻删除涉嫌侵权内容。
a5200
更换
双机
上一篇新闻:mysqlbinlog用法
下一篇新闻:实战:tcpdump抓包分析三次握手四次挥手
猜你喜欢
香港多ip虚拟主机租用需要备案吗
自架云服务器有哪些优点和缺点
云服务器系统镜像有什么用
免费论坛虚拟主机软件有哪些
免费论坛虚拟主机搭建要注意什么
电脑开机密码忘了怎么办
怎么启用javascript功能
linux云服务器连接的方法是什么
云服务器ping端口不通怎么解决
安徽虚拟主机空间租用怎么搭建