C/C++ 通过ADO对数据库操作
实例:c++ 通过ADO调用存储过程写入数据到sql server
1.在.h头文件导入微软提供的ado的动态库
#pragma warning(disable:4146)
#import "C:\\Program Files\\Common Files\\System\\ado\\msado15.dll" named_guids rename("EOF","adoEOF"), rename("BOF","adoBOF")
#pragma warning(default:4146)
using namespace ADODB;
2.编写函数调用存储过程
//保存数据库记录
void SaveDbTran(char *devID,char * traceNo,char *refNo,char *batchNo, char * bankCardNo, char * tranDate, char * tranTime,char * amt,char * hosCardNo,char * hosName,char * hosIDCardNo, char *msg)
{
//2.1创建数据库连接句柄
_ConnectionPtr pMyConnect;
HRESULT hr;
try
{
//2.1.1组建连接数据库字符串
char *dbConStr = new char[400];
strcpy(dbConStr,"Provider=SQLOLEDB;Server=sqlserver服务器地址,1433;Database=数据库名;uid=登陆用户;pwd=登录密码");
CoInitialize(NULL);
Sleep(300);
//2.1.2 句柄实例化 实现连接
hr = pMyConnect.CreateInstance("ADODB.Connection");
if(SUCCEEDED(hr))
{
ct.SaveLog("创建数据库连接对象成功,等待打开连接",0,dbConStr);
pMyConnect->Open(_bstr_t(dbConStr),"","",adModeUnknown);
}
else
{
CoUninitialize();
return;
}
}
catch(_com_error &err)
{
CoUninitialize();
return ;
}
//2.2组建运行命令参数句柄
_CommandPtr m_pCommand;
_RecordsetPtr m_pRecordset;
try
{
//2.2.1 句柄实例化
m_pCommand.CreateInstance(__uuidof(Command));//Command无需改变
m_pCommand->ActiveConnection = pMyConnect;//pMyConnect 为连接数据库句柄
m_pCommand->CommandType = adCmdStoredProc;//adCmdStoredProc无需改变
m_pCommand->CommandText = _bstr_t("p_d_tra");//p_d_tra为存储过程名
//2.2.2 设置给可变参数赋值
_variant_t vv_dotype,vv_TranNo,vv_devID,vv_TranDate,vv_TranTime;
_variant_t vv_RetCode,vv_BusType,vv_CardNo,vv_IDCard,vv_Name;
_variant_t vv_Amt,vv_Notes,vv_SerID,vv_DesCont,vv_tranFlag;
_variant_t vv_bankCardNo,vv_bankGroupNo,vv_bankFlowNo,vv_DevName,vv_ExeCount;
// value to variant
vv_dotype =_variant_t(_bstr_t("1"));
vv_TranNo =_variant_t(_bstr_t(temp_traceNo));
vv_devID =_variant_t(_bstr_t(devID));
vv_TranDate =_variant_t(_bstr_t(datetime));
vv_TranTime =_variant_t(_bstr_t(datetime));
vv_RetCode =_variant_t(_bstr_t(""));
vv_BusType =_variant_t(_bstr_t("14"));
vv_CardNo =_variant_t(_bstr_t(hosCardNo));
vv_IDCard =_variant_t(_bstr_t(hosIDCardNo));
vv_Name = _variant_t(_bstr_t(hosName));
vv_Amt =_variant_t(_bstr_t(amt));
vv_Notes =_variant_t(_bstr_t("交易成功"));
vv_SerID =_variant_t(_bstr_t(""));
vv_DesCont =_variant_t(_bstr_t(""));
vv_tranFlag =_variant_t(_bstr_t("0"));
vv_bankCardNo =_variant_t(_bstr_t(temp_bankCardNo));
vv_bankGroupNo=_variant_t(_bstr_t(batchNo));
vv_bankFlowNo =_variant_t(_bstr_t(refNo));
vv_DevName =_variant_t(_bstr_t(""));
vv_ExeCount = _variant_t(ret_ExeCount);
//2.2.3创建数据库存储过程输入参数
_ParameterPtr mp_dotype,mp_TranNo,mp_devID,mp_TranDate,mp_TranTime;
_ParameterPtr mp_RetCode,mp_BusType,mp_CardNo,mp_IDCard,mp_Name;
_ParameterPtr mp_Amt,mp_Notes,mp_SerID,mp_DesCont,mp_tranFlag;
_ParameterPtr mp_bankCardNo,mp_bankGroupNo,mp_bankFlowNo,mp_DevName,mp_ExeCount;
//2.2.3.1给数据库参数实例化
//create ParameterPtr instance
mp_dotype.CreateInstance(__uuidof(Parameter));
mp_TranNo.CreateInstance(__uuidof(Parameter));
mp_devID.CreateInstance(__uuidof(Parameter));
mp_TranDate.CreateInstance(__uuidof(Parameter));
mp_TranTime.CreateInstance(__uuidof(Parameter));
mp_RetCode.CreateInstance(__uuidof(Parameter));
mp_BusType.CreateInstance(__uuidof(Parameter));
mp_CardNo.CreateInstance(__uuidof(Parameter));
mp_IDCard.CreateInstance(__uuidof(Parameter));
mp_Name.CreateInstance(__uuidof(Parameter));
mp_Amt.CreateInstance(__uuidof(Parameter));
mp_Notes.CreateInstance(__uuidof(Parameter));
mp_SerID.CreateInstance(__uuidof(Parameter));
mp_DesCont.CreateInstance(__uuidof(Parameter));
mp_tranFlag.CreateInstance(__uuidof(Parameter));
mp_bankCardNo.CreateInstance(__uuidof(Parameter));
mp_bankGroupNo.CreateInstance(__uuidof(Parameter));
mp_bankFlowNo.CreateInstance(__uuidof(Parameter));
mp_DevName.CreateInstance(__uuidof(Parameter));
mp_ExeCount.CreateInstance(__uuidof(Parameter));
//2.2.3.2将数据库参数追加到 命令变量句柄的参数属性末尾
//append parameterPtr set to _CommandPtr parameters lists
//数据库参数 = 命令变量句柄->创建参数方法(_bstr_t("存储过程参数名"),存储过程参数数据类型,存储过程参数输入输出类型,默认大小,可变参数值)
mp_dotype=m_pCommand->CreateParameter(_bstr_t("dotype"),adInteger,adParamInput,-1,vv_dotype);//整数类型
m_pCommand->Parameters->Append(mp_dotype);
mp_TranNo=m_pCommand->CreateParameter(_bstr_t("TranNo"),adVarChar,adParamInput,32,vv_TranNo); //字符串类型
m_pCommand->Parameters->Append(mp_TranNo);
mp_devID=m_pCommand->CreateParameter(_bstr_t("devID"),adVarChar,adParamInput,20,vv_devID);
m_pCommand->Parameters->Append(mp_devID);
mp_TranDate=m_pCommand->CreateParameter(_bstr_t("TranDate"),adVarChar,adParamInput,25,vv_TranDate);//时间类型
m_pCommand->Parameters->Append(mp_TranDate);
mp_TranTime=m_pCommand->CreateParameter(_bstr_t("TranTime"),adVarChar,adParamInput,25,vv_TranTime);
m_pCommand->Parameters->Append(mp_TranTime);
mp_RetCode=m_pCommand->CreateParameter(_bstr_t("RetCode"),adVarChar,adParamInput,20,vv_RetCode);
m_pCommand->Parameters->Append(mp_RetCode);
mp_BusType=m_pCommand->CreateParameter(_bstr_t("BusType"),adInteger,adParamInput,-1,vv_BusType);
m_pCommand->Parameters->Append(mp_BusType);
mp_CardNo=m_pCommand->CreateParameter(_bstr_t("CardNo"),adVarChar,adParamInput,20,vv_CardNo);
m_pCommand->Parameters->Append(mp_CardNo);
mp_IDCard=m_pCommand->CreateParameter(_bstr_t("IDCard"),adVarChar,adParamInput,20,vv_IDCard);
m_pCommand->Parameters->Append(mp_IDCard);
mp_Name=m_pCommand->CreateParameter(_bstr_t("Name"),adVarChar,adParamInput,10,vv_Name);
m_pCommand->Parameters->Append(mp_Name);
mp_Amt=m_pCommand->CreateParameter(_bstr_t("Amt"),adDecimal,adParamInput,10,vv_Amt);//浮点数类型
mp_Amt->NumericScale = 2; //设置小数点后位数
mp_Amt->Precision = 10; //设置整数位位数
m_pCommand->Parameters->Append(mp_Amt);
mp_Notes=m_pCommand->CreateParameter(_bstr_t("Notes"),adVarChar,adParamInput,2000,vv_Notes);
m_pCommand->Parameters->Append(mp_Notes);
mp_SerID=m_pCommand->CreateParameter(_bstr_t("SerID"),adVarChar,adParamInput,20,vv_SerID);
m_pCommand->Parameters->Append(mp_SerID);
mp_DesCont=m_pCommand->CreateParameter(_bstr_t("DesCont"),adVarChar,adParamInput,2000,vv_DesCont);
m_pCommand->Parameters->Append(mp_DesCont);
mp_tranFlag=m_pCommand->CreateParameter(_bstr_t("tranFlag"),adInteger,adParamInput,-1,vv_tranFlag);
m_pCommand->Parameters->Append(mp_tranFlag);
mp_bankCardNo=m_pCommand->CreateParameter(_bstr_t("bankCardNo"),adVarChar,adParamInput,25,vv_bankCardNo);
m_pCommand->Parameters->Append(mp_bankCardNo);
mp_bankGroupNo=m_pCommand->CreateParameter(_bstr_t("bankGroupNo"),adVarChar,adParamInput,12,vv_bankGroupNo);
m_pCommand->Parameters->Append(mp_bankGroupNo);
mp_bankFlowNo=m_pCommand->CreateParameter(_bstr_t("bankFlowNo"),adVarChar,adParamInput,12,vv_bankFlowNo);
m_pCommand->Parameters->Append(mp_bankFlowNo);
mp_DevName=m_pCommand->CreateParameter(_bstr_t("DevName"),adVarChar,adParamInput,40,vv_DevName);
m_pCommand->Parameters->Append(mp_DevName);
mp_ExeCount=m_pCommand->CreateParameter(_bstr_t("ExeCount"),adInteger,adParamOutput,-1,vv_ExeCount);//输出类型
m_pCommand->Parameters->Append(mp_ExeCount);
//2.2.4 执行得到结果
_variant_t vNull;
vNull.vt = VT_ERROR;
vNull.scode = DISP_E_PARAMNOTFOUND;
//2.2.4.1执行数据库存储过程
m_pRecordset = m_pCommand->Execute(&vNull,&vNull,adCmdStoredProc);//adCmdStoredProc不要改变
//m_pRecordset执行SQL结果 可对其进行判断确定成功,错误原因
if (mp_ExeCount->Value != 0)
{
ct.SaveLog("插入数据失败",0,"");
}
else
{
ct.SaveLog("插入数据成功",0,"");
}
}
catch(_com_error &err)
{
if(pMyConnect->State) pMyConnect->Close();
pMyConnect = NULL;
CoUninitialize();
}
//2.2.5 关闭连接 释放资源
if(pMyConnect->State) pMyConnect->Close();
pMyConnect = NULL;
CoUninitialize(); //切记成功与否都要调用 以释放资源
return ;
}
免责声明:本站发布的内容(图片、视频和文字)以原创、转载和分享为主,文章观点不代表本网站立场,如果涉及侵权请联系站长邮箱:is@yisu.com进行举报,并提供相关证据,一经查实,将立刻删除涉嫌侵权内容。