lscfg -vp |grep -i -p dimm 查看内存的详细信息
root@test:/# lscfg -vp |grep -i -p dimm Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C1 Customer Card ID Number.....31D2 Serial Number...............YLD004400864 CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C1 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C2 Customer Card ID Number.....31D2 Serial Number...............YLD006406476 CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C2 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C3 Customer Card ID Number.....31D2 Serial Number...............YLD0008A7715 CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C3 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C4 Customer Card ID Number.....31D2 Serial Number...............YLD00240DB7B CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C4 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C7 Customer Card ID Number.....31D2 Serial Number...............YLD00340DAD3 CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C7 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C8 Customer Card ID Number.....31D2 Serial Number...............YLD00140D72C CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C8 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C9 Customer Card ID Number.....31D2 Serial Number...............YLD00740DA98 CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C9 Memory DIMM: Record Name.................VINI Flag Field..................XXMS Hardware Location Code......U78AA.001.WZSGZ30-P1-C18-C10 Customer Card ID Number.....31D2 Serial Number...............YLD00540DBCA CCIN Extender...............1 Product Specific.(VZ).......03 FRU Number..................77P8919 Part Number.................77P8919 Power.......................4800000000010000 Size........................8192 Product Specific.(HE).......0001 Product Specific.(CT).......10210004 Product Specific.(HW).......0001 Product Specific.(B3).......030000000001 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C18-C10 root@test:/#
lscfg -vp |grep -p PROC 查看CPU的详细信息
root@test:/# lscfg -vp |grep -p PROC 4-WAY PROC CUOD: Record Name.................VINI Flag Field..................XXPF Hardware Location Code......U78AA.001.WZSGZ30-P1-C11 Customer Card ID Number.....535E Serial Number...............B00000702332 FRU Number..................74Y6152 Part Number.................74Y6152 Product Specific.(HE).......0001 Product Specific.(CT).......40110004 Product Specific.(HW).......0001 Product Specific.(B3).......000000000000 Product Specific.(B4).......00 Product Specific.(B7).......000000000000000000000000 Power.......................3400400122028000 Product Specific.(VZ).......01 CCIN Extender...............1 Version.....................ipzSeries Physical Location: U78AA.001.WZSGZ30-P1-C11 PROC REGULATOR : Record Name.................VINI Flag Field..................XXRG Hardware Location Code......U78AA.001.WZSGZ30-P1-C12 Customer Card ID Number.....51CB Serial Number...............YL14211951BN Part Number.................74Y8421 FRU Number.................. 74Y8421 CCIN Extender...............1 Product Specific.(VZ).......02 Product Specific.(CR)....... Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-P1-C12 root@test:/#
lscfg -vp |grep -p -i 'A IBM AC PS' 查看电源的详细信息
root@test:/# lscfg -vp |grep -p -i 'A IBM AC PS' A IBM AC PS : Record Name.................VINI Flag Field..................XXPS Hardware Location Code......U78AA.001.WZSGZ30-E1 Customer Card ID Number.....2BCB Serial Number...............YL10219N0583 Part Number.................74Y9082 FRU Number.................. 74Y9082 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-E1 A IBM AC PS : Record Name.................VINI Flag Field..................XXPS Hardware Location Code......U78AA.001.WZSGZ30-E2 Customer Card ID Number.....2BCB Serial Number...............YL10219N0615 Part Number.................74Y9082 FRU Number.................. 74Y9082 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-E2 root@test:/#
lscfg -vp |grep -p -i 'IBM Air Mover' 查看风扇的详细信息
root@test:/# lscfg -vp |grep -p -i 'IBM Air Mover' IBM Air Mover : Record Name.................VINI Flag Field..................XXAM Hardware Location Code......U78AA.001.WZSGZ30-A1 Customer Card ID Number.....6B1D FRU Number.................. 74Y5220 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-A1 IBM Air Mover : Record Name.................VINI Flag Field..................XXAM Hardware Location Code......U78AA.001.WZSGZ30-A2 Customer Card ID Number.....6B1D FRU Number.................. 74Y5220 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-A2 IBM Air Mover : Record Name.................VINI Flag Field..................XXAM Hardware Location Code......U78AA.001.WZSGZ30-A3 Customer Card ID Number.....6B1D FRU Number.................. 74Y5220 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-A3 IBM Air Mover : Record Name.................VINI Flag Field..................XXAM Hardware Location Code......U78AA.001.WZSGZ30-A4 Customer Card ID Number.....6B1D FRU Number.................. 74Y5220 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-A4 IBM Air Mover : Record Name.................VINI Flag Field..................XXAM Hardware Location Code......U78AA.001.WZSGZ30-P1-C1-A1 Customer Card ID Number.....6B1C FRU Number.................. 74Y5221 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-P1-C1-A1 IBM Air Mover : Record Name.................VINI Flag Field..................XXAM Hardware Location Code......U78AA.001.WZSGZ30-P1-C1-A2 Customer Card ID Number.....6B1C FRU Number.................. 74Y5221 Version.....................RS6K Physical Location: U78AA.001.WZSGZ30-P1-C1-A2 root@test:/#
另外使用lscfg -vpl sysplanar0能够查到上面所有的信息